Read the two digits properly
First digit = solids (dust). Second digit = water. IP65: dust-tight + water jets. IP66: dust-tight + powerful jets. IP67: brief immersion. IP68: continuous immersion, depth defined by manufacturer. For signage: rain exposure starts at IP65; driving monsoon rain justifies IP66; flood-prone or wash-down locations want IP68.
What ratings don't tell you
- UV stability. An IP68 module can still yellow in three summers if the housing isn't UV-stabilized ABS/PC. Ask for the material spec.
- Sealing process consistency. A rating describes a test unit, not your batch. Ask whether every batch is sampled for immersion/jet testing, not just the certification unit.
- Temperature range. Desert installs need −20°C to +70°C tolerance; ask for the operating range, not just the IP number.
Three questions that separate real factories from re-labelers
- How is potting applied — full-pot or bead — and with which compound?
- Is batch-level IP sampling documented, and can I see records?
- What is the rated operating temperature range of this exact model?
SANLUM modules carry IP65–IP68 options with full-pot sealing and batch test records. Request the sealing test documentation with your sample order.